Understanding ambient temperature storage
Medicines manufacturers may define ambient storage temperature as being within a variety of different ranges between 8ºC and 30ºC. If there are specific requirements, these will be stated on the packaging.
In our guidance, we use “ambient temperature” as a general term and include advice related to specific ranges where necessary. Medicines may be stored at ambient temperature in a variety of different areas including:
- a Pharmacy store or dispensary
- a ward or clinic medicines cupboard
- an ambulance
- a GP surgery
- a community midwife’s bag
Ideally, all medicines storage areas would be controlled between 15ºC and 25ºC, which is suitable for all ambient medicines. Pharmacy departments are expected to be able to provide this level of temperature control for medicines. In practice, many locations do not have air conditioning that gives this level of control. Nevertheless, there are steps that can be taken to optimise ambient storage areas.
Optimising temperature control
Air conditioning should be installed, if possible.
Store medicines away from radiators and warm air ventilation inlets. Direct sunlight may create hot spots, especially in summer. If this is the case, consider moving affected medicines into a shaded location or adding reflective film to the windows.
Keep windows and doors closed as much as possible. Windows may be opened to aid cooling but only if it is cooler outside, and be cautious of security risks.
If air conditioning cannot be installed, consider the use of ambient storage cabinets for small quantities of stock. These look like fridges or incubators but the chamber is maintained between 15ºC and 25ºC. The principles outlined in our article on using fridges and freezers to store medicines will apply if ambient storage units are used.
Consider temperature mapping to identify warm spots and cool spots, and re-organising the storage accordingly. Medicines that may be stored down to 8ºC could be stored in the coolest spots or medicines with no specific storage requirements could be stored in the warmer spots.
Monitoring ambient areas
Monitor the temperature within the storage area. For more information refer to our article series about temperature monitoring.
Heatwaves and exceptionally cold weather
Actions such as those described above are not always possible, or do not give full assurance that the temperature is reliably controlled. If it is foreseeable that there will be temperature excursions in warm or cool weather, steps can be taken pro-actively to minimise their impact.
Information on managing unexpected temperature excursions can be found in our series on managing temperature excursions.
High temperatures and heatwaves
Monitor stock turnover closely; keep stock levels to the minimum and ensure stock is strictly rotated:
- for high stock turnover areas, this means that the medicines will only be exposed to high temperatures for a brief time before being used
- for low stock turnover areas, this means that the minimum quantity of medicines will be affected by the excursion
A system of manually reducing the expiry date on medicines that are frequently exposed to temperatures a few degrees above their required storage temperature may also be used. Some medicines also have additional information in their SmPCs permitting storage at higher temperatures.
Low temperatures
Most medicines that require ambient storage do not have a lower temperature limit. Those that do may precipitate or solidify at low temperatures. In some cases, this precipitation is reversible and will be explained in the SmPC. In other cases, precipitation may not be reversible so these medicines need to be protected from routine low excursions of any duration.